4. Testing items and eligibility criteria
4.1 Power limit:
4.1.1 Emission power limit:
4.1.1.1 The conducted emission power shall conform to regulations stated in Appendix 1 and the deviation of rated output power value shall be within±2.7dB.
4.1.1.2 The effective isotropic radiated power (EIRP) shall conform to the effective isotropic radiated power (EIRP) specified in the Technical Specifications for Mobile Broadband Base Station Radio Frequency Equipment and be tested during the examination of base station.
4.1.2 Testing methods:
4.1.2.1 During the measurement of emission power, one must use devices with RMS (root mean square) equivalent voltage to measure any continuous transmission time. The measurement results shall be used to adjust the correct emission power based on the responding time, resolution bandwidth capability and sensitivity of the device.
4.1.2.2 Testing channels include three channels (low, medium and high) that test emission patterns with the maximum modulation level of different operating bandwidths.
4.2 Radiation emission limit outside the conduction band:
4.2.1 Any free radiation emission outside the operating band shall be lower than the carrier emission power (P) and the measurement is calculated in Watt. The edge attenuation outside the operating channel shall be higher than 43 + 10 log (P) dB.
4.2.2 Testing methods:
4.2.2.1 Devices with an operating frequency lower than 1GHz.
4.2.2.1.1 Within a range that is outside the edge of measurement channel and within 1 GHz out-of-band, the measurement shall be conducted by using spectrum measurement apparatuses with a resolution bandwidth above 100 kHz; as for an out-of-band range that is over 1 GHz, the measurement shall be conducted by using spectrum measurement apparatuses with a resolution bandwidth above 1 MHz.
4.2.2.1.2 Within a range of 100 kHz that is outside the channel edge, a smaller resolution bandwidth shall be used to measure the radiation outside the accurate channel. At this moment, the minimum resolution bandwidth must be higher than 30 kHz.
4.2.2.1.3 Testing channels include three channels (low, medium and high) that test emission patterns with the maximum modulation level of different operating bandwidths.
4.2.2.2 Devices with an operating frequency higher than 1 GHz.
4.2.2.2.1 Within a range that is outside the edge of measurement channel and within 1 GHz out-of-band, the measurement shall be conducted by using spectrum measurement apparatuses with a resolution bandwidth above 100 kHz; as for an out-of-band range that is over 1 GHz, the measurement shall be conducted by using spectrum measurement apparatuses with a resolution bandwidth higher than 1 MHz.
4.2.2.2.2 Within a range of 1 MHz that is outside the channel edge, a smaller resolution bandwidth shall be used to measure the radiation outside the accurate channel. At this moment, the minimum resolution bandwidth must be higher than 1% of the carrier emission bandwidth (26 dB bandwidth). However, the maximum shall not be over 100 kHz.
4.2.2.2.3 Testing channels include three channels (low, medium and high) that test emission patterns with the maximum modulation level of different operating bandwidths.
4.3 Electrical safety:
Shall comply with standard specifications stated in CNS 14336-1.
4.4 Electromagnetic compatibility (EMC):
Shall comply with standard specifications stated in CNS 13438.