4. Frequency Range
4.1 Test purpose
500MHz Trunked Radio Terminal:
To verify that Trunked Radio Terminal shall operate within the frequency bands from 507.4375MHz to 509.950MHz and from 523.9375MHz to 526.450MHz.
800MHz Trunked Radio Terminal:
To verify that Trunked Radio Terminal shall operate within the frequency band from 810.5MHz to 812MHz and from 855.5MHz to 857MHz.
4.2 Conformance requirement
500MHz Trunked Radio Terminal:
Tx band: 523.9375 ~ 526.450 MHz (Tx)
Rx band: 507.4375 ~ 509.950 MHz (Rx)
800MHz Trunked Radio Terminal:
Tx band: 810.5 ~ 812 MHz (Tx)
Rx band: 855.5 ~ 857 MHz (Rx)
4.3 Method of measurement
The MS or HS should be situated in an isolated environment from any radio system without transmitting.
The MS or HS should be switched-on and set in a transmitting (carrier-on) mode for the test required the highest and lowest frequency of the applicant's assignment.
The MS or HS should be switched-on and set in a receiving (carrier-off) mode. The signal generator shall be set at any channel of the allocated frequency, and transmit 1,000Hz audio tone signal modulated with 3,000Hz and 1mV output power level to EUT. The EUT shall receive the signal.
In case, the EUT is of a digital modulation, to transmit the signal according to the modulation mode and output power level in itself to the spectrum analyzer.
The spectrum analyzer shall be set in sweep mode and shall be operated under the following conditions:
Frequency range: as required for frequency range to be assessed
Resolution bandwidth: no less than 100KHz
Display bandwidth: equal to the measurement bandwidth
Averaging: no
Peak hold: yes
4.4 Test requirement
The test requirements are given in Annex A, and measurement shall be set up as Annex B. In the test equipment, the spectrum analyzer noise floor shall be at least 6dB below the appropriate limits of 65dB.